Manual J, Manual S, Manual D, and REScheck compliance certificates. We act as your external HVAC engineering department, delivering calculations tailored for New Jersey building inspection.
Detailed room-by-room ACCA Manual J load sizing
Every package is designed to meet strict local municipal submittal requirements and ACCA standards.
Calculates room-by-room heating and cooling loads based on local climate design temperatures, envelope insulation, windows orientation, infiltration, and occupant loads.
Verifies that the selected HVAC equipment matches the calculated sensible and latent loads, selecting heating capacity and airflows based on manufacturer performance data.
Computes proper duct sizes, static pressure drops, and airflow parameters (CFM) for each register to guarantee uniform ventilation and thermal balance throughout the building.
Verifies building envelope energy efficiency limits (insulation R-values, window performance U-values) to meet strict New Jersey energy compliance regulations.
In case local building subcode reviewers issue comments or ask for calculation revisions, we handle them directly with no additional fee to ensure you obtain your construction permit.
You receive clean, organized PDF compliance files containing structural calculation results, loads breakdowns, and hardware data logs ready to submit to building officials.
AirCalc is not just a software tool or an automated calculator. We are an specialized HVAC calculations engineering service. Our technicians review architectural plans manually, apply ASHRAE and ACCA formulas, verify local compliance with New Jersey Uniform Construction Code, and deliver permit-ready reports.
From plan review upload to municipal permit approval, we verify compliance at every milestone.
Start by entering building layout parameters, conditioned area, and contact details.
Upload architectural blueprints in PDF, DWG/CAD, or readable image formats.
Choose between Manual J (loads), Manual S (equipment), Manual D (ducts), or the full JSD + REScheck package.
Our technicians verify plans, solar orientation, insulation U/R values, and local design temperatures.
We run precise heating and cooling load computations following ACCA and ASHRAE standards.
A senior engineer validates and reviews the calculation results to certify optimizations.
We compile final files, room-by-room load details, and submittal summaries.
Receive final certified and signed digital reports ready for municipal building code submittal.
If the construction code official issues comments or objections, we revise calculations at no extra cost.
Drag the slider to input the total conditioned square footage of your project and see instant package estimates.
Room-by-room heating & cooling loads
Manual J + Manual S + Manual D
Disclaimer: Disclaimer: Final quotes may vary slightly based on layout complexity, multiple HVAC zones, custom ceiling heights, or additions requiring separate heat transfer parameters.
Every document is compiled to standard submittal format, minimizing review delays by building officials.
Total heating/cooling loads, peak sensible and latent gains, design criteria calculations.
Performance sizing check verifying equipment selection meets cooling/heating capacities.
Total external static pressure limit, airflows CFM list, duct size allocations.
Energy code compliance certificate indicating building envelope pass margins.
Individual load calculations for each room/zone to optimize HVAC balance.
Sensible heat ratios, fan curves, and specific manufacturer ratings verification.
Provide your details and upload project drawings to receive a custom design review.